Tu, Jian et al. published their research in Journal of Pharmaceutical and Biomedical Analysis in 2005 | CAS: 5367-32-8

3-Methyl-4-nitroanisole (cas: 5367-32-8) belongs to ethers. Ethers are good solvents partly because they are not very reactive. Most ethers can be cleaved, however, by hydrobromic acid (HBr) to give alkyl bromides or by hydroiodic acid (HI) to give alkyl iodides. Ethers are good solvents partly because they are not very reactive. Most ethers can be cleaved, however, by hydrobromic acid (HBr) to give alkyl bromides or by hydroiodic acid (HI) to give alkyl iodides.Synthetic Route of C8H9NO3

Estimation of log Pow values for neutral and basic compounds by microchip microemulsion electrokinetic chromatography with indirect fluorimetric detection (μMEEKC-IFD) was written by Tu, Jian;Halsall, H. Brian;Seliskar, Carl J.;Limbach, Patrick A.;Arias, Francisco;Wehmeyer, Kenneth R.;Heineman, William R.. And the article was included in Journal of Pharmaceutical and Biomedical Analysis in 2005.Synthetic Route of C8H9NO3 This article mentions the following:

Microchip microemulsion electrokinetic chromatog. with indirect fluorimetric detection (μMEEKC-IFD) was used to obtain log P octanol/water (log Pow) values for neutral and basic compounds Six compounds, with log Pow values between 0.38 and 5.03, were used to create a calibration curve relating the log of retention factors (log k) obtained from μMEEKC-IFD with the known log Pow values. The log Pow values for six addnl. compounds were determined using the log k values obtained by μMEEKC-IFD and the linear relationship between log Pow and log k established for the standard compounds The μMEEKC-IFD buffer was composed of 50 mM 3-[cyclohexylamino]-1-propane-sulfonic acid (CAPS) buffer (pH 10.4) containing 1.2% n-heptane (volume/volume), 2% sodium dodecylsulfate (w/v), 8% 1-butanol (volume/volume) and 4 μM 5-carboxytetramethyl-rhodamine (TAMRA) as the fluorophore probe for indirect detection. The μMEEKC-IFD provided an accurate method for estimating log Pow values and also a means for analyzing compounds that are non-fluorescent. In the experiment, the researchers used many compounds, for example, 3-Methyl-4-nitroanisole (cas: 5367-32-8Synthetic Route of C8H9NO3).

3-Methyl-4-nitroanisole (cas: 5367-32-8) belongs to ethers. Ethers are good solvents partly because they are not very reactive. Most ethers can be cleaved, however, by hydrobromic acid (HBr) to give alkyl bromides or by hydroiodic acid (HI) to give alkyl iodides. Ethers are good solvents partly because they are not very reactive. Most ethers can be cleaved, however, by hydrobromic acid (HBr) to give alkyl bromides or by hydroiodic acid (HI) to give alkyl iodides.Synthetic Route of C8H9NO3

Referemce:
Ether – Wikipedia,
Ether | (C2H5)2O – PubChem